Broadcom released patches on November 24, 2026, for a critical authentication bypass in VMware vCenter Server, tracked as CVE-2026-123903. The flaw sits in the VMware Directory Service on the vCenter appliance, which typically runs Photon Linux. Broadcom rated it 9.8 out of 10 on the CVSS scale and said a malicious actor with network access to vCenter may bypass authentication and gain unauthorized access to the system. The company said there is no workaround.
The advisory arrives 5 days after Broadcom fixed a similar Directory Service bypass, CVE-2026-123890, that Google said a suspected China-linked group had exploited as a zero-day since early September. In its FAQ, Broadcom said the new bug is a distinct issue and is not the same as last week’s flaw. Broadcom has not said CVE-2026-123903 has been exploited in the wild. As of November 24, the CVE was not yet listed in the National Vulnerability Database, and CISA had not added it to the Known Exploited Vulnerabilities catalog.
What Broadcom fixed
The fix is in Broadcom’s VMware Security Advisory VMSA-2026-0011. Broadcom credited mochazz of sglab of Qianxin, Qi Qin of depthfirst, and VulTeam and XGTP from ThreatBook with independently reporting the vCenter authentication bypass. A supplemental FAQ says the issue qualifies as an emergency change.
Fixed versions for the vCenter issue include:
- vCenter 9.1.x:
9.1.2 - vCenter 9.0.x:
9.0.2.0300 - vCenter 8.0:
8.0 U3m - VMware Cloud Foundation 5.x:
5.2.5 - vCenter 7.0: no public fix; Broadcom tells customers with extended support contracts to contact support
VMware Telco Cloud Platform and Telco Cloud Infrastructure are also affected; Broadcom points those customers to a separate knowledge base article. The same advisory, which covers 23 CVEs in total, also patches critical bugs in ESX, Workstation and Fusion, plus other issues in VMware Tools and Avi Load Balancer. Updating vCenter does not update those other products.
Administrators who already applied vCenter 8.0 U3m for last week’s advisory, including on Cloud Foundation 5.2.x, do not need to patch vCenter again. That build is also the 8.0 fix in this advisory. vCenter 9.1.x still needs 9.1.2, and vCenter 9.0.x needs 9.0.2.0300, one step past the 9.0.2.0200 build released for CVE-2026-123890.
How this differs from last week’s flaw
Last week, Broadcom patched CVE-2026-123890, another critical authentication bypass in the VMware Directory Service, also rated 9.8, with no workaround. As BreachNews reported, Google Threat Intelligence Group and Mandiant said the suspected China-nexus group ARMORY CASTLE had used that bug in early September, months before the November 19 patch, to create administrator sessions and steal vCenter directory data. CISA added CVE-2026-123890 to its Known Exploited Vulnerabilities catalog on November 20 and gave federal civilian agencies until November 23 to apply Broadcom’s fixes or mitigations.
Broadcom’s FAQ is clear that CVE-2026-123903 is a new and distinct issue, so a patch for last week’s bug is not by itself a fix on every branch. The exception is vCenter 8.0 systems that already run 8.0 U3m. Broadcom has not reported in-the-wild exploitation of the new CVE, and the two should not be treated as the same event.
What defenders should do
Broadcom’s guidance is to install one of the fixed versions listed in the advisory. Patches are cumulative, so a newer build than the one named in the response matrix also contains the fix. Because there is no workaround, teams that cannot patch immediately should limit network access to vCenter management interfaces to trusted administrator systems only.
Organizations that were exposed to last week’s exploited flaw should still hunt for leftover access, including unexpected SSO administrator or machine accounts, as Google recommended after the ARMORY CASTLE report. A clean patch to CVE-2026-123903 does not remove an attacker who is already inside.